We are Manufacturer, Supplier, Exporter of LT Detuned Reactors, Series Reactor For Power Factor Correction and our set up is situated in Pune, Maharashtra, India.

LT Detuned Reactors

LT Detuned Reactors


LT Detuned Reactors

LT Detuned Reactors

Salient Features of SAGAON Reactors :

  • Specially Designed Bobbins for efficient Cooling
  • Multiple Conductors for better Heat dissipation
  • Vacuum Pressure Impregnated for better penetration
  • Multiple Air Gaps to avoid Flux Fringing
  • Mechanically Sturdy Design To Withstand Vibrations
  • Thermal Switch embedded To Withstand Vibrations
  • Thermal Switch embedded in winding for over temperature Protection
  • Low Noise

Type :
  • Detuned, Iron Core, Copper or Aluminum Wound

Range :
  • From 5 KVAR to 300 KVAR
  • Filter Factor 5.67 %, 7 %, 14 %
  • System Voltage : 440 V, 550 V, 690

Benefits of using SAGAON Reactors :
  • Increase life of capacitors
  • Reduce harmonics in Electrical Systems
  • Avoid over heating of cables of Transformers
  • Avoid over current during switching of capacitor banks

Technical Specifications :
  • Standards Followed : IS -5553-1990
  • Linearity: Standard 1.73 Times on request 2.08 Times.
  • Insulation Class H as Standard, F on Request
  • Inductance Value Accuracy within +, - 1.5%
  • Termination : For Copper Wound -Nickel Platted Copper busbar for 25 KVAR & above For Aluminum Wound -Aluminum Lugs
  • Noise level less than 60 dB at rated load at I meter Distance
  • Inductance phase within +1.2%
  • Adequate cushion provided to avoid heating due to leakage flux


Typical Data Sheet For 440V, 7% Detuned, Copper Wound Reactors :

Value
Dimensions (in mm)
Current
Inductance
Weight (in Kg)
Losses
Watts
 
L
W
H
       
10 KVAR 7%
220
130
165
13.2 A
4.64 mH
15
80W
12.5 KVAR 7%
220
130
165
16.6 A
3.71 mH
15
90W
15 KVAR 7%
220
160
165
19.8 A
3.1 mH
20
130W
25 KVAR 7%
225
145
205
33 A
1.86 mH
24
170W
50 KVAR 7%
260
170
230
65.8 A
0.926 mH
35
250W
75 KVAR 7%
300
175
270
99 A
0.618 mH
47
340W
100 KVAR 7%
300
200
265
131.5 A
0.464 mH
58
380W


Typical Data Sheet For 440V, 7% Detuned, Aluminium Wound Reactors :

Value
Dimensions (in mm)
Current
Inductance
Weight (in Kg)
Losses
Watts
 
L
W
H
       
10 KVAR 7%
220
150
160
13.2 A
4.64 mH
8.7
90W
12.5 KVAR 7%
240
160
165
16.6 A
3.71 mH
10
90W
15 KVAR 7%
230
170
205
19.8 A
3.1 mH
16.3
125W
25 KVAR 7%
250
180
205
33 A
1.86 mH
20
170W
50 KVAR 7%
290
205
235
65.8 A
0.926 mH
27
250W
100 KVAR 7%
340
250
270
131.5 A
0.464 mH
49
380W


Our Other Products :
  • Transformers : VPI, Cast Resin, Oil Filled
  • Input & Output Reactor for Drives
  • Impedance Bonds For Railway Signalling
  • DC Air Core Reactors for Steel Mills
  • Dual Inductance DC Iron Core Reactors
LT Detuned Reactors

LT Detuned Reactors


request-quote